GENESIS-LDX-095

■ 設計靈活性、繞組、直徑和堆疊長度
■ 多功能集成:粘結、夾具、螺紋轂、通孔
■ 直接扭矩傳輸的卓越動態性能
■ 緊湊型電機架構

規格

095-013B

LDX 095 013

095-025B

LDX 095-025

095-038B

LDX 095-038

095-050B

LDX 095-050

095-075B

LDX 095-75

 

PerformanceUnits095-013B095-025B095-038B095-050B095-075B
Max. Continuous Torque*Nm2.344.585.967.4310.0
Continuous Current*Arms2.264.173.813.543.16
Peak Torque @ 20°CNm4.078.6412.216.324.4
Peak CurrentArms4.208.508.508.508.50
Rated Power*W479913862829762
Speed at Rated PowerRPM2,1682,2941,5831,187791
Torque at Rated PowerNm2.113.805.206.679.20
No-Load SpeedRPM3,1372,9872,1141,5851,057
Cogging Torque% of Continuous2.52.52.52.52.5
ElectricalUnits095-013B095-025B095-038B095-050B095-075B
Design Voltage**
48 VDC available upon request
VAC230230230230230
Ke at 20°C (± 10 %)Vrms/kRPM73.377.0109145218
Kt loaded at 120°CNm/Arms1.041.101.562.103.18
Km at 20°CNm/√(W)0.3130.5430.6640.7921.00
Km at 120°CNm/√(W)0.2270.3970.4890.5870.750
Resistance line-to-line at 20°C (± 10 %)10.03.674.906.128.57
Inductance line-to-line at 20°C (± 10 %)mH29.714.521.728.943.33
ThermalUnits095-013B095-025B095-038B095-050B095-075B
Thermal Resistance °C/W0.9330.7520.6750.6250.558
Aluminum Heat Sink Dimensionsmm250 x 250 x 6.3250 x 250 x 6.3250 x 250 x 6.3250 x 250 x 6.3250 x 250 x 6.3
Storage Temperature°C-20 to 80-20 to 80-20 to 80-20 to 80-20 to 80
Operating Ambient Temperature***°C-20 to 80-20 to 80-20 to 80-20 to 80-20 to 80
Maximum Winding Temperature°C120120120120120
PhysicalUnits095-013B095-025B095-038B095-050B095-075B
Stator ODmm95.095.095.095.095.0
Rotor IDmm30.030.030.030.030.0
Stator Lengthmm29.542.054.567.092.0
Stator Sleeve Lengthmm14.527.039.552.077.0
Stator Stack Lengthmm12.525.037.550.075.0
Rotor Lengthmm13.527.039.552.077.0
Rotor Inertiakg·m24.70E-059.25E-041.38E-041.83E-042.74E-04
Total Masskg0.681.111.541.972.83
Number of Poles2020202020
Integrated Sensors095-013B095-025B095-038B095-050B095-075B
Temperature SensorPT-1000PT-1000PT-1000PT-1000PT-1000

*Assumes a 100°C temperature rise from 20°C ambient to the maximum winding temperature.

**Motors can be operated at different voltages. Contact an Applications Engineer for inquiries with special voltage requirements.

***Increasing the ambient temperature de-rates motor performance.