GENESIS-LDX-180

■ 設計靈活性、繞組、直徑和堆疊長度
■ 多功能集成:粘結、夾具、螺紋轂、通孔
■ 直接扭矩傳輸的卓越動態性能
■ 緊湊型電機架構

規格

180-013B

LDX 180-013

180-025B

LDX 180-025

180-050B

LDX 180-050

180-075B

LDX 180-075

180-100B

LDX 180-100

PerformanceUnits180-013B180-025B180-050B180-075B180-100B
Max. Continuous Torque*Nm13.224.442.356.067.3
Continuous Current*Arms4.286.256.707.657.01
Peak Torque @ 20°CNm23.446.993.8143188
Peak CurrentArms7.7212.215.220.020.0
Rated Power*W9371,3741,5461,7821,654
Speed at Rated PowerRPM815678421373277
Torque at Rated PowerNm11.019.435.145.657.0
No-Load SpeedRPM1,088862535463352
Cogging Torque% of Continuous2.02.02.02.02.0

 

ElectricalUnits180-013B180-025B180-050B180-075B180-100B
Design Voltage**
48 VDC available upon request
VAC230230230230230
Ke at 20°C (± 10 %)Vrms/kRPM211267430497653
Kt loaded at 120°CNm/Arms3.073.906.317.329.60
Km at 20°CNm/√(W)1.141.882.943.714.30
Km at 120°CNm/√(W)0.8521.412.212.803.24
Resistance line-to-line at 20°C (± 10 %)6.223.683.893.274.20
Inductance line-to-line at 20°C (± 10 %)mH16.012.616.314.118.7

 

ThermalUnits180-013B180-025B180-050B180-075B180-100B
Thermal Resistance °C/W0.4200.3330.2740.2500.232
Aluminum Heat Sink Dimensionsmm400 x 400 x 12.7400 x 400 x 12.7400 x 400 x 12.7400 x 400 x 12.7400 x 400 x 12.7
Storage Temperature°C-20 to 80-20 to 80-20 to 80-20 to 80-20 to 80
Operating Ambient Temperature***°C-20 to 80-20 to 80-20 to 80-20 to 80-20 to 80
Maximum Winding Temperature°C120120120120120
PhysicalUnits180-013B180-025B180-050B180-075B180-100B
Stator ODmm179179179179179
Rotor IDmm104104104104104
Stator Lengthmm29.542.067.092.0117
Stator Sleeve Lengthmm14.527.052.077.0102
Stator Stack Lengthmm12.525.050.075.0100
Rotor Lengthmm14.527.052.077.0102
Rotor Inertiakg·m21.42E-032.78E-035.50E-038.22E-031.09E-02
Total Masskg1.572.654.836.959.10
Number of Poles4444444444
Integrated Sensors180-013B180-025B180-050B180-075B180-100B
Temperature SensorPT-1000PT-1000PT-1000PT-1000PT-1000

*Assumes a 100°C temperature rise from 20°C ambient to the maximum winding temperature.

**Motors can be operated at different voltages. Contact an Applications Engineer for inquiries with special voltage requirements.

***Increasing the ambient temperature de-rates motor performance.

All electrical and performance specifications have +/- 15% tolerance. Specifications are preliminary and subject to change.